產(chǎn)品簡(jiǎn)介
ZahnradpumpenAggregate
Gear PUMP unitS
2 Tabelle 1: Übersicht R25 (Drehzahl 1450 1/min, kinematische Viskosität 33 mm /s)
2 table 1: R25 summary (speed 1450 rpm, kinematic viscosity 33 mm /s)
Phone + 49 (0) 23 75 / 9 27-0
Fax + 49 (0) 23 75 / 9 27-26
E-Mail kontakt@rickmeier.de
RICKMEIER GmbH
Langenholthauser Str. 20-22
58802 Balve
Zahnradpumpen Ventile Sonderprodukte Systeme
P U M P E N T E C H N O L O G I E
@www.rickmeier.de
R25
Form 229595-4 (09/02)
1) Standardpumpe ohne Ventil, Motorbauform IM B35: Mehrgewicht für DB- bzw.
GLRD-Ausführung siehe zugehöriges Pumpendatenblatt
1) standard pump without valve, motor design IM B35; excess weight for
DB - respectively GLRD-version p.r.t. pertaining pump data sheet
The technical details in this catalog have
been provided for general information.
For any assembly, operation.servicing
do respect the operating manuals and
the instructions provided on the products.
Technical data, product range and
order data, accessories.availability
are subject to alteration. All dimensions
in this catalog are in millimetres.
This catalog supersedes catalog P5
Die technischen Angaben in diesem
Katalog dienen der allgemeinen Information.
Bei Montage, Betrieb und
Wartung sind die Betriebsanleitungen
und die auf den Produkten angegebenen
Hinweise unbedingt zu beachten.
Änderungen der technischen
Daten, Auswahl- und Bestelldaten, beim
Zubehör und der Lieferbarkeit sind vorbehalten.
Alle Abmessungen in diesem
Katalog gelten in Millimeter.
Ungültig: Katalog P5
Pumpenaggregate R25
Zahnradpumpenaggregate werden
standardmäßig mit Drehstrom-Asynchronmotoren
gemäß DIN EN 50347 ausgerüstet.
Auf Anfrage sind auch Einphasen-Wechselstrommotoren
sowie Gleichstrommotoren verschiedenster
Spannungsebenen erhältlich. Zur
Auswahl des für Ihren Anwendungsfall passenden
Aggregats können Sie die rechtsstehende
Tabelle 1 verwenden.
Die in den Maßtabellen angegebenen Motormaße,
die nicht in DIN EN 50347 genormt sind,
beziehen sich auf unser Standardfabrikat (spezielle
Hersteller sind auf Anfrage erhältlich). In
Tabelle 1 finden Sie die zu den angegebenen
Austrittsdrücken und Förderströmen gehörigen
Motorleistungen bei einer kinematischen Vis-
2 kosität des Fördermediums von 33 mm /s und
einer Drehzahl von 1450 1/min. Für abweichende
Drehzahlen können die Förderströme
näherungsweise proportional umgerechnet
werden. Die zum gewählten Aggregat gehörigen
Abmessungen finden Sie auf den folgenden
beiden Seiten in der Zeile, auf die rechts in
Tabelle 1 verwiesen wird.
Für Bahn-, Schiffs- oder andere Anwendungen
mit besonderen Schwingungsbeanspruchungen
empfehlen wir für den Pumpenträgerfuß
die schwere Bauform. Hierdurch ändert sich
das Bohrbild der Fußbefestigung, Abmessungen
auf Anfrage.
RICKMEIER
Gear pump units
RICKMEIER motor gear pump units as a
standard are equipped with three-phase asynchronous
motors under DIN EN 50347. When
so requested, single-phase a.c. motors.d.c.
motors are available at different voltages. To
. the motor that fits for your application
please refer to table 1 on the right-hand side.
The dimensions of the motors specified in the
table of dimensions, which have not been
standardised under the DIN EN 50347, relate to
our standard brand (special manufactures are
available on request). In table 1 you will find the
motor outputs relating to the specified outlet
pressures.flow rates for a kinematic
2 viscosity of the flow medium of 33 mm /s.a
speed of 1450 rpm. For different numbers of
revolutions it is possible to convert the flow
rates approximately proportional to speed. You
will find the dimensions for the .ed unit on
the following two pages in the line that has been
referred to in table 1 on the right-hand side.
For rail, ship.other applications with specific
vibrating stresses we recommend a heavy duty
design for the unit support. This will result in
changes of the hole pattern for the support
attachment. Dimensions can be provided on
request.
[cm3] [dm3 /min] [MPa] [bar] BG [kW] [kg]
2,5 2,7 1,00 10,0 71M 0,25 11,0 1
3,15 3,5 1,00 10,0 71M 0,25 11,0 1
4 4,2 1,00 10,0 71M 0,25 11,0 1
5,4 0,90 9,0 71M 0,25 11,0 1
5,0 1,58 15,8 71M 0,37 11,5 1
7,4 0,78 7,8 71M 0,25 11,0 1
6,7 1,30 13,0 71M 0,37 11,5 1
6,7 2,12 21,2 80M 0,55 14,5 2
9,9 0,63 6,3 71M 0,25 11,0 1
9,3 1,02 10,2 71M 0,37 11,5 1
8,6 1,54 15,4 80M 0,55 14,5 2
8,4 2,50 25,0 80M 0,75 16,0 2
12,8 0,49 4,9 71M 0,25 11,0 1
12,3 0,85 8,5 71M 0,37 11,5 1
11,7 1,43 14,3 80M 0,55 14,5 2
11,0 2,06 20,6 80M 0,75 16,0 2
10,9 2,50 25,0 90S 1,10 18,5 3
16,3 0,45 4,5 71M 0,25 11,5 4
15,8 0,80 8,0 71M 0,37 12,5 4
15,4 1,30 13,0 80M 0,55 15,0 5
14,9 1,80 18,0 80M 0,75 16,5 5
14,0 2,50 25,0 90S 1,10 19,5 6
21,2 0,30 3,0 71M 0,25 11,5 4
20,9 0,55 5,5 71M 0,37 12,5 4
20,5 0,95 9,5 80M 0,55 15,0 5
20,2 1,35 13,5 80M 0,75 16,5 5
19,2 2,10 21,0 90S 1,10 19,5 6
18,7 2,50 25,0 90L 1,50 22,5 7
26,8 0,15 1,5 71M 0,25 11,5 4
26,5 0,40 4,0 71M 0,37 12,5 4
26,3 0,70 7,0 80M 0,55 15,0 5
26,1 1,05 10,5 80M 0,75 16,5 5
25,2 1,65 16,5 90S 1,10 19,5 6
24,3 2,30 23,0 90L 1,50 22,5 7
23,5 2,50 25,0 100L 2,20 33,5 8
Gewicht1)
weight 1)
Maße siehe
Tabelle 2 - Zeile ..
for dimensions p.r.t.
table 2 - line ..
5
6,3
Förderstrom
flow rate
max. zul.
Differenzdr.
max. permiss.
diff. press.
Vg
displ.
vol.
Normmotor
standard motor
Größe
size
Leistg.
output
20