LCA15重量變送器LCA20
Load Cell Amplifier with Data Outputs RS232 & RS485
LCA20 Product Sheet Issue 1.0 27.03.14 mantracourt.com
[email protected] tel +44 (0)1395 232020
LCA20 & LCB20
Load Cell Amplifier with Data Outputs RS232 & RS485
User Benefits
Improved stability of load cell input
Improved analogue output response time
Full digital set-up.calibration using keypad.PC
Easy load cell sensitivity selecion set by PC.keypad
Analogue.data output, set point.display capabilities AC.DC powered
Simple one pass calibration
New comms module
Easy configuration using LCA Toolkit software
Available with DIN Rail mounting.PCB module.a stainless steel case
Ideal Applications
Civil Engineering
Agriculture
Industrial Processing
The LCA15 has been redesigned to become the LCA20 taking advantage of new technology with improved performance.increased functionality. The external appearance.dimensions of the LCA20 remains the same as the LCA15.
In addition to the introduction of a new microprocessor.using the latest RISC technology, the LCA20 has many new features such as the .ion of device parameters via a PC.keypad rather than using the traditional on-PCB switches.
A PCB only version, which can be DIN rail mounted, is also available as the LCB20.
RS485.RS232 digital data output for communications.printing
Measurement speeds 10 / 80 samples per sec
Factory calibration in mV/V
5 V excitation supports up to 10 x 350 R load cells
Fully isolated 4-20 mA.0-10 V analogue outputs
6 wire input to compensate for barrier.cable losses
2 set points SPCO relay outputs
Sensitivity from 0.5 to 7.8 mV/V
10 pt linearization
3 x configurable digital inputs e.g. for auto tare, peak hold.reset
Firmware now supports Mantrabus 1 & 2, MANTRA ASCII 2 & MODBUS RTU
ROHS Compliant & Environmentally sealed to IP65 / NEMA 4 enclosure dimensions 200 x 120 x 75 mm
Introduction
Specification at a Glance
The ROHS Compliant LCA20 flexible digital signal conditioning amplifier for multiple.single load cell applications, offering very easy one-pass calibration
and fast set-up
New Design PCB
New LCA Toolkit Software
LCA20 Product Sheet Issue 1.0 27.03.14 mantracourt.com
[email protected] tel +44 (0)1395 232020
For more information contact us today…
mantracourt.com
[email protected] Mantracourt Electronics Ltd
The Drive, Farringdon, Exeter,
Devon, EX5 2JB, UK
T: +44 (0) 1395 232020
F: +44 (0) 1395 233190
In the interests of continued product development, Mantracourt Electronics Limited reserves the right to .product specifications without prior notice
LCB20
Digital load cell amplifier with data & relay outputs
ADP15
Universal digital panel meter for measuring 4-20 mA, 0-10 V
LC4
RS485/232 Communications (supports MODBUS RTU, ASCII,
MANTRABUS 1 & MANTRABUS 2)
PGM1
Programming cable for the LCA20
LCA Toolkit
Quick set up software event monitoring, data logging, calibration.configuration
Instrument Explorer
Quick set up software event monitoring, data logging, calibration.configuration
The Application:
The supplier of a plant based herbal product had a problem with potential decay-causing organisms affecting the quality of the material during processing.subsequent storage. The solution lay in the use of a chemical spray which would protect the product from degradation. However, to be effective, the spray has to be applied in precise quantities (parts per million).
The Solution:
The chemical spray rate is based on the product flow rate through the manufacturing process. The system developed was made up of five Mantracourt integrated ADP15 indicator display.s.an LCA20 weighing amplifier/digitiser module unit supported by the LCA Toolkit software.
During the process the product flows over a chute which has a load cell mounted on a pivot. The load cell weighs the product as it flows down the chute.transmits this to the LCA20. The LCA20 reads the product flow rate from the load cell in kilograms per hour.transmits this as a 4-20 mA signal to the ADP15 instruments. This data, in turn, allows an accurate (and also efficient) use of the treatment spray.
Storage temperature
Operating temperature
Relative humidity
IP Rating
- 20 to +70oC
- 10 to +50oC
95% maximum non condensing
IP65 / NEMA 4
CE Environmental Approvals
European EMC Directive
Low Voltage Directive
2004/108/EC
2006/95/EC